A solution for not displaying the parameter panel

  • Last update:October 13, 2021
  • I. Overview

    1) Problem Overview

    Sometimes, when we run a well-designed report through certain operations, the parameter panel suddenly doesn't show up. How can we solve this situation?

    Design interface:

    1.png

    Preview interface:

    2.png

    2) Solutions

    Open the corresponding CPT file in a text editor, find the showWindow property under The ReportParameterAttr TAB, change its value from"false" to "true", and save it in UTF-8 bom free format.

    II.  Example

    1) Open the Template

    Open with a text editor:%FR_HOME%\webapps\webroot\WEB-INF\reportlets\doc-EN\Parameter\Dynamic Table.cpt.

    2) Modify the Template

    Find the showWindow property under the ReportParameterAttr tag, change its value from false to true, and save it in UTF-8 bomfree format.

    4.png

    3) Effect Preview

    3.png


    Attachment List


    Theme: Rachel
    Already the First
    Already the Last
    • Helpful
    • Not helpful
    • Only read

    滑鼠選中內容,快速回饋問題

    滑鼠選中存在疑惑的內容,即可快速回饋問題,我們將會跟進處理。

    不再提示

    10s後關閉

    Get
    Help
    Online Support
    Professional technical support is provided to quickly help you solve problems.
    Online support is available from 9:00-12:00 and 13:30-17:30 on weekdays.
    Page Feedback
    You can provide suggestions and feedback for the current web page.
    Pre-Sales Consultation
    Business Consultation
    Business: international@fanruan.com
    Support: support@fanruan.com
    Page Feedback
    *Problem Type
    Cannot be empty
    Problem Description
    0/1000
    Cannot be empty

    Submitted successfully

    Network busy