A solution for not displaying the parameter panel

  • Last update:  2021-10-13
  • I. Overview

    1) Problem Overview

    Sometimes, when we run a well-designed report through certain operations, the parameter panel suddenly doesn't show up. How can we solve this situation?

    Design interface:

    1.png

    Preview interface:

    2.png

    2) Solutions

    Open the corresponding CPT file in a text editor, find the showWindow property under The ReportParameterAttr TAB, change its value from"false" to "true", and save it in UTF-8 bom free format.

    II.  Example

    1) Open the Template

    Open with a text editor:%FR_HOME%\webapps\webroot\WEB-INF\reportlets\doc-EN\Parameter\Dynamic Table.cpt.

    2) Modify the Template

    Find the showWindow property under the ReportParameterAttr tag, change its value from false to true, and save it in UTF-8 bomfree format.

    4.png

    3) Effect Preview

    3.png