Data Volume Description

  • Last update:July 08, 2026
  • Overview

    Version

    FineBI Version
    Functional Change

    7.0

    /

    Application Scenario

    Improper operations by some FineBI users may disrupt other users or degrade system performance, and such risks need to be mitigated.

    FineBI provides data volume limits on the data editing page of analysis subjects to avoid such issues, ensuring the normal use of FineBI.

    Function Entry

    You can set the number of records for calculation when editing data in an analysis subject, as shown in the following figure.

    Function Description

    Data Volume Limit Tier

    Data volume for calculation can be configured in the editing mode of an analysis subject. The following table shows the available rows for data calculation corresponding to different data volume settings.


    Option

    Data Volume for a Dataset

    Data Volume for a Component/Dashboard

    Extraction

    First 100,000 Rows

    100,000 Rows

    100,000 Rows

    First 10000,000 or Full Volume   (Default setting)

    10000,000 Rows

    • Unupdated subject: 10,000,000 Rows

    • Updated subject: Full Volume

    Direct Connection

    First 100,000 Rows

    100,000 Rows

    100,000 Rows

    First 10000,000 or Full Volume   (Default setting)

    Full Volume

    Full Volume

    Data Volume Limit for the Source Table

    The source tables of all resources in the subject are only affected by the data volume limit of the current subject (no longer affected by the update status of parent tables to avoid data unavailability).

    The row count of source tables for datasets is limited. For example, dataset A contains source tables B and C.

    • For direct connection datasets, the data volume of B and C is fixed as the full volume.

    • For extracted datasets, only 100,000 rows or 10,000,000 rows can be switched for data volume.

    Notes

    Starting from FineBI V6.0.8, if the source table (parent table) of the editing data has not been extracted, the switching option will be grayed out, and only the first 100,000 rows of data will be used for calculation, as shown in the following figure.

    11111111.png

    The following content shows the scenarios where the source table is not extracted:

    1. The source table is a non-simplest table that is currently not extracted.

    2. The source table is the simplest table that is never extracted. The simplest table must be a published and non-Excel-uploaded self-service dataset and meet the following two conditions:

    • No associations established

    • Tables only involving a table selection step or a table selection step with a non-field-type-conversion field setting step

    附件列表


    主题: Adding and Editing Data
    Previous
    Next
    • Helpful
    • Not helpful
    • Only read

    滑鼠選中內容,快速回饋問題

    滑鼠選中存在疑惑的內容,即可快速回饋問題,我們將會跟進處理。

    不再提示

    10s後關閉

    Get
    Help
    Online Support
    Professional technical support is provided to quickly help you solve problems.
    Online support is available from 9:00-12:00 and 13:30-17:30 on weekdays.
    Page Feedback
    You can provide suggestions and feedback for the current web page.
    Pre-Sales Consultation
    Business Consultation
    Business: international@fanruan.com
    Support: support@fanruan.com
    Page Feedback
    *Problem Type
    Cannot be empty
    Problem Description
    0/1000
    Cannot be empty

    Submitted successfully

    Network busy