FineDataLink supports connection to Pulsar to fetch real-time data from Pulsar by configuring the Pulsar consumer.
Real-Time Task supports data reading from and writing into Pulsar.
Collect the following information before connection.
WebService address
Broker address
Username and password (which is required if you set Authentication Method to Username Password)
Place the driver package in \webapps\webroot\WEB-INF\lib path in the FineDataLinik installation directory before connection.
1. Log in to FineDataLink, choose System Management > Data Connection > Data Connection Management, and choose Create > Data Connection, as shown in the following figure.
2. Find the Pulsar icon, as shown in the following figure.
3. Fill in the connection information.
The configuration items are described in the following table.
Set the Pulsar address
For example, http://demo.fanruan.com:8080.
An HTTPS URL is also supported.
Set the broker address.
For example, http://demo.fanruan.com:6650.
No Authentication
JWT Authentication: Set the token.
Username Password: Set the username and password.
4. Click Test Connection. If the connection is successful, click Save to save the configuration.
Only Real-Time Task supports the Pulsar data connection currently.